School Locker Quantity Planner — How Many Tiers 300 Students Actually Need Per Corridor

Locker quantity is where school projects go wrong in both directions. Order one locker per student with generous doors and the corridor disappears; order compact tiers to save wall and the coats stop fitting by October. The fix is arithmetic, not guesswork — the door heights are standardized, the bank sizes are fixed, and 300 students plus a tape measure gives you the answer in ten minutes. This guide runs the full calculation with real bank footprints, then maps which tier suits which age group. Figures come from Hengna’s 2026 ABS locker module family.
The Rule That Decides Everything: One Door, One Student
Start with the assignment model, because it multiplies everything after it. One door per student is the standard — every child gets a compartment, no sharing, no schedule coordination. Some schools rotate cohorts through shared compartments, which halves the count but doubles the logistics: two students per door means two combination codes, two cleaning obligations and a dispute path. Post-2020, most schools dropped rotation and went back to one-per-student. This guide assumes one door per student; if your school runs rotation, halve the bank counts below and accept the coordination cost.
The Module Family: Fixed Sizes, Simple Math
ABS locker banks come in fixed configurations, which is what makes the planning honest — you are choosing among defined boxes, not estimating custom carpentry. Every bank in the standard family runs three columns wide:
| Configuration | Doors per bank | Bank size W × D × H (mm) | Banks for 300 students | Total wall run |
|---|---|---|---|---|
| Full height, 1 tier | 3 | 1146 × 500 × 1940 | 100 | ≈ 115 m |
| 2 tiers | 6 | 1146 × 500 × 1940 | 50 | ≈ 57 m |
| 3 tiers (low unit) | 9 | 1196 × 420 × 960 | 34 | ≈ 41 m |
| 4 tiers | 12 | 1146 × 500 × 1940 | 25 | ≈ 29 m |
| 5 tiers | 15 | 1146 × 500 × 1940 | 20 | ≈ 23 m |
| 6 tiers | 18 | 1146 × 500 × 1940 | 17 | ≈ 19.5 m |
Two readings of that table matter more than the rest. First, wall run drops fast as tiers rise — 6-door banks eat 57 meters of corridor for 300 students, while 18-door banks need under 20. Second, “wall run” is one side of one corridor; most schools split banks across grade floors, which shrinks each run to a manageable strip.
Door Height: What Actually Fits at Each Tier
Tier count is really a decision about door height, and door height decides what a student can store:
- 930 mm doors (2 tiers) — full bags plus hanging jackets and coats. The secondary-school workhorse.
- 620 mm doors (3 tiers) — bags, lunch boxes and folded jackets; long coats fold over the rod.
- 465 mm doors (4 tiers) — school bags and book stacks, no hanging space.
- 372 mm and 310 mm doors (5–6 tiers) — bags and books only. Popular in tight corridors where jackets stay on corridor hooks anyway.
- Compact banks — small-door units for phones, lunch boxes and pencil cases in primary settings.

The module diagram shows the 2-tier unit’s numbers: a 930 mm door on a 382 × 500 mm footprint, roughly 900 × 350 × 470 mm of clearance inside each compartment. Hold a school bag against those numbers before choosing anything smaller — a bag that needs a shove is a bag that gets kicked, week after week.
Matching Tiers to Age Groups
The age mapping is where planners earn their fee. Primary students carry less and reach less: the low 9-door unit — 960 mm tall overall — puts every compartment inside a child’s reach without stools, and the compact phone-and-lunch configurations suit younger grades. Secondary students carry more and hang coats year-round: 2-tier or 3-tier banks with 620–930 mm doors, kept at full height for self-service. Mixed campuses solve it by floor — low units in the primary wing, tall banks in the secondary wing — using the same color program throughout so the campus reads as one system.
The Corridor Reality Check
Wall run is only half the corridor question; depth is the other half. A bank at 500 mm deep projects half a meter into the corridor, and students standing at open doors need standing room behind them. Before finalizing counts, measure the corridor clear width, subtract the bank depth, and confirm what remains for two-way foot traffic — and put your local fire egress code in charge of the final say, because minimum aisle widths are set by regulation, not by this planner. If the corridor fails the test, the answers are already in the table above: more tiers per bank, or split the run across more floors.
Worked Example: 300 Students, Three Grade Floors
Take the common case — a secondary school, 300 students, one door each, three grade floors. Choosing 6-door banks: 50 banks total, about 17 per floor, a run of roughly 19.5 meters per floor against one corridor wall. Choosing 12-door banks: 25 banks, just over 8 per floor, a 9.5-meter run per floor — the same students, a third of the wall, at the cost of coat-hanging height. That trade — wall length versus door height — is the entire decision, and now it has numbers attached.
Wayfinding rides along free with the same order. Molded number plates on every door — not paper cards — survive a school year of wet gloves and scraped bags, and two of the 8 standard colors per grade floor let the youngest students find their bank by color before they can read a room number. Color plus number costs nothing extra on volume orders and removes most first-week corridor chaos on its own.
Where Hengna Fits In
Luoyang Hengna Office Furniture Co., Ltd. builds the ABS module family behind these numbers: 2 to 27 door banks, door widths from 290 to 480 mm, depths from 390 to 500 mm, overall heights from 860 to 2100 mm, all in injection-molded ABS with mortise-and-tenon tool-free assembly. Schools order on a manufacturer-direct basis with OEM options for logos, custom colors on volume, and knock-down export packing. Warranty is one year; quotes come back within 24 hours with the bank counts worked out from your student numbers.
Common Questions
Can two students share one compartment?
Physically yes, practically it costs more than it saves — two codes, two cleaning schedules, and disputes over whose bag is whose. Most schools that tried rotation after 2020 went back to one door per student.
What if our corridor cannot fit the run?
Move up the tier table: more tiers per bank shrinks the wall run at the cost of door height. Splitting banks across more floors works too — the planner table gives both numbers.
Do the low 9-door units need a base?
They sit at 960 mm overall including the 80 mm molded base, sized so young students reach every door without stools. Raising them further defeats the point.
How long does assembly take across a whole school?
Banks assemble tool-free on site — snap-fit panels, no drilling. A maintenance team banks several units per hour; a 50-bank project is days, not weeks, and quotes should confirm the schedule.
Can we order sample banks before the full roll-out?
Yes. Sample orders covering one corridor are accepted, and container quantities for the full roll-out bring the better unit pricing.